SpectraBase Spectrum ID |
9zeomAQnknB |
Name |
4-Fluoro-2-(trifluoromethyl)benzenesulfonyl chloride |
Source of Sample |
TCI Chemicals India Pvt. Ltd. |
Catalog Number |
F1124 |
Lot Number |
P4Z4O-CS |
Accessory |
TRANS *14560FA0 |
Acquisition Mode |
double sided, forward-backward |
Actual Signal Gain |
2 |
Actual Signal Gain 2nd Channel |
1 |
Additional Data Treatment |
0 |
Analog Signal 1 |
0.270567 |
Analog Signal 2 |
0 |
Aperture Setting |
6 mm |
Apodization Function |
Norton-Beer, medium |
Background Measurement Channel |
Sample Compartment |
Background Peak Amplitude 2nd Channel |
1 |
Background Peak Location 2nd Channel |
1 |
Background Scans |
32 |
Background Scans or Time |
Scans |
Backward Peak Amplitude |
-10402 |
Backward Peak Location |
14450 |
Beam Splitter Setting |
KBr |
CAS Registry Number |
176225-09-5 |
Color Properties |
White-reddish yellow |
Container ID |
C-009712 |
Copyright |
Copyright © 2018-2024 John Wiley & Sons, Inc. All Rights Reserved. |
Data Point Format |
1 |
Delay Before Measurement |
0 s |
Detector Setting |
RT-DLaTGS [Internal] |
End Frequency Limit for File |
340 |
External Synchronization |
Off |
Focal Length |
100 |
Formula |
C7H3ClF4O2S |
Frequency of First Point |
3999.54 cm⁻¹ |
Frequency of Last Point |
339.945 cm⁻¹ |
High Folding Limit |
15800.5 |
High Frequency Limit |
8000 cm⁻¹ |
High Pass Filter |
0 |
InChI |
InChI=1S/C7H3ClF4O2S/c8-15(13,14)6-2-1-4(9)3-5(6)7(10,11)12/h1-3H |
InChIKey |
IGMYEVQPXWKFQF-UHFFFAOYSA-N |
Instrument Name |
Bruker Tensor 27 FT-IR |
Laser Wavenumber |
15800.5 cm⁻¹ |
Low Folding Limit |
0 |
Low Frequency Limit |
0 |
Low Pass Filter |
10 |
Molecular Weight |
262.606 g/mol |
Non Linearity Correction |
0 |
Number of Points |
15180 |
Number of Sample Scans |
32 |
Optical Filter Setting |
Open |
Peak Amplitude |
-10782 |
Peak Amplitude 2nd Channel |
1 |
Peak Location |
14506 |
Peak Location 2nd Channel |
1 |
Phase Correction Mode |
Mertz |
Phase Resolution |
4 |
Physical State |
Solid |
Preamplifier Gain Background |
0 |
Purity |
98% |
Relative Humidity Interferometer |
10 % |
Resolution |
2 |
SKU |
F1124-1G |
SMILES |
C(F)(F)(F)c1cc(ccc1S(=O)(=O)Cl)F |
Sample Spacing Divisor |
1 |
Sample Spacing Multiplicator |
1 |
Scan Time |
50.037 s |
Scanner Temperature |
29.6 °C |
Scanner Velocity |
10 kHz |
Signal Gain, Background |
automatic |
Solvent |
Dichloromethane |
Source of Spectrum |
Bio-Rad Laboratories, Inc. |
Start Frequency Limit for File |
4000 cm⁻¹ |
Synonyms |
2-(Chlorosulphonyl)-4-fluorobenzotrifluoride |
Technique |
Film |
Window |
KBr Window |
Zero Filling Factor |
8 |